DWDM

DWDM
DWDM
AAWG DWDM

Athermal AWG DWDM 16 ~ 48 Channel 100GHz in 1U/2U Rack

お問い合わせカート Optical Specifications Product features Download
ParameterMin.Typ.Max.Unit.Note. Number of Channels16, 20, 24, 32, 40, 44, 4816, 20, 24, 32, 40, 44, 4816, 20, 24, 32, 40, 44, 48   Number Channel Spacing100100100GHz  Center WavelengthC-bandC-bandC-bandnm  Clear Channel Pass Band±0.1±0.1±0.1nm  Wavelength Stability±0.05±0.05±0.05Nm  -1dB Channel Bandwidth0.24  nm  -3dB Channel Bandwidth-0.43  nm  Optical Insertion Loss at ITU grid 4.56.0dB1 Adjacent Channel Isolation25  dB  Non-Adjacent Channel Isolation29  dB  Total Channel Isolation22  dB  Insertion Loss Uniformity 0.80.5dB1 Insertion Loss Ripple  1.2dB1 Optical Return Loss40  dB  PDL / Polarization Dependent Loss 0.30.5dB2 Polarization Mode Dispersion  0.5Ps  Maximum Optical Power  23dBm  Monitoring Range-35 +23dBm  Note 1. The Insertion Loss values not including Connector Loss.Note 2. 16CH & 18CH are with Band Splitter. High Stability and ReliabilityLow Insertion LossLow PDLHigh Channel IsolationNo electrical power requiredNo temperature control required
ParameterMin.Typ.Max.Unit.Note. Center Wavelength RangeC61(1528.77nm) ~ C15(1565.50nm) per ITU-GridC61(1528.77nm) ~ C15(1565.50nm) per ITU-GridC61(1528.77nm) ~ C15(1565.50nm) per ITU-GridC61(1528.77nm) ~ C15(1565.50nm) per ITU-Grid  Channel Spacing100GHz ( 0.8nm )100GHz ( 0.8nm )100GHz ( 0.8nm )100GHz ( 0.8nm )  Fiber TypeSMF-28e or equivalent Single Mode FiberSMF-28e or equivalent Single Mode FiberSMF-28e or equivalent Single Mode FiberSMF-28e or equivalent Single Mode Fiber  Center Wavelength Accuracy±0.05±0.05±0.05nm  Channel Passband (@-0.5dB) (nm)0.220.220.22nm  Passband Ripple (dB)  0.5;dB  Optical Insertion Loss at ITU grid ( for MUX or DEMUX only, not for Pair Loss of MUX+DEMUX )4CH8CH16CH 1 Optical Insertion Loss at ITU grid ( for MUX or DEMUX only, not for Pair Loss of MUX+DEMUX )<1.8<3.0<4.0dB1 Optical Insertion Loss at ITU grid ( for MUX or DEMUX only, not for Pair Loss of MUX+DEMUX )24CH32CH40CH 1 Optical Insertion Loss at ITU grid ( for MUX or DEMUX only, not for Pair Loss of MUX+DEMUX )<4.8<5.6<6.2dB1 Adjacent Channel Isolation30  dB  Non-Adjacent Channel Isolation40  dB  PDL / Polarization Dependent Loss  0.2dB2 PMD / Polarization Mode Dispersion  0.1ps  Optical Return Loss40  dB  PDirectivity50  dB  Maximum Optical Power  0.5Ps  Maximum Optical Power  300mW  1U 19” Rack-Mount Dimension-432(W) x 44(H) x 200(D)-432(W) x 44(H) x 200(D)-432(W) x 44(H) x 200(D)mm3 Note 1. . IL represents the worst case over a ±0.08nm window around the ITU wavelength without Connector Loss.Note 2. PDL was measured on average polarization over a ±0.08nm window around the ITU wavelength.Note 3. The Width Dimension 432mm is for the main package body only. High Stability and ReliabilityLow Insertion LossLow PDLHigh Channel IsolationNo electrical power requiredNo temperature control required